VANDE BHARAT – SALOON – SLEEPER - 8 TR / 28.1 KW

Basic Technical Parameters
Sr.No. Parameters
Electrical Requirement
1 Power Supply 3 Phase, 415 V ± 5%, 50 Hz ± 3%
2 Power Consumption 17.5* kVA
Capacity
1 Cooling Capacity 28.1 kW/8 Tr (With Interlaced Evaporator Coil)
2 Heating Capacity 9.0 kW
Constructional Requirement
1 Design to Ambient 50°C
2 Max Operating Temperature 55°C
3 Dimension (LxWxH) 2565 x 2000 x 545 mm
4 Material for Housing AL5083 H111
5 Noise Level(Inside Coach) 70dB from 1 meter distance
6 Controller Microprocessor Controller as per RDSO Spec. No.: RDSO/PE/SPEC/AC/0139-(Rev.1)-2009
7 Refrigrant R-407C
8 Weight 570 kg approx
Service condition
1 Ambient -10 to 55°C
2 Max. Temp. inside coach Under Sun 70°C
3 Train Speed 200 Km/h
4 Relative Humidity Maximum Up to 98%
5 Atmosphere Extremly dusty & desert weather
6 Shock & Vibration Standard IEC 61373