CAB AC - CLW - 2 TR / 7 KW

Basic Technical Parameters
Sr.No. Parameters
Electrical Requirement
1 Power Supply 3 Phase, 415 V ±5%, 50 Hz ±3%
2 Power Consumption 3.5 kW
Capacity
1 Cooling Capacity 7 kW/2 Tr
2 Heating Capacity 2.0 kW
Constructional Requirement
1 Design to Ambient (Cooling) 50°C / 35°C
2 Max Operating Temperature 60°C
3 Dimension (LxWxH) 1146 x 1000 x 290 mm
4 Material for Housing SS 304 grade S2 Confirming to IS:6911
5 Noise Level(Inside the Coach) 65 dB
6 Controller Electronic Thermostat/Solid stat temp control to RDSO/PE/SPEC/AC/0020. (Latest Alt.)
7 Refrigrant R-407C
8 Weight 150 kg Approx.
Service condition
1 Ambient -4 to 50°C
2 Max. Roof Temp. 70°C
3 Train Speed 160 Km/h
4 Relative Humidity Up to 100% during rainy season
5 Atmosphere Very dusty atmosphere with dust of composite brake block shoe.
6 Shock & Vibration Standard IEC 61373