CAB AC – VANDE BHARAT - 2 TR / 7 KW
Basic Technical Parameters
Sr.No.
Parameters
Electrical Requirement
1
Power Supply
3 Phase, 415 V ±5%, 50 Hz ±3%
2
Power Consumption
3.3 kW
Capacity
1
Cooling Capacity
7 kW/2 Tr
2
Heating Capacity
2.0 kW
Constructional Requirement
1
Design to Ambient (Cooling)
50°C / 35°C
2
Max Operating Temperature
60°C
3
Dimension (LxWxH)
1308 x 1061 x 291 mm
4
Material for Housing
SS 304 grade S2 Confirming to IS:6911
5
Noise Level(Inside the Coach)
65 dB
6
Controller
Microprocessor Controller as per RDSO Spec. No.: RDSO/PE/SPEC/AC/0020-(latest)
7
Refrigrant
R-407C
8
Weight
145 kg Approx.
Service condition
1
Ambient
-4 to 50°C
2
Max. Roof Temp.
70°C
3
Train Speed
160 Km/h
4
Relative Humidity
Up to 100% during rainy season
5
Atmosphere
Very dusty atmosphere with dust of composite brake block shoe.
6
Shock & Vibration Standard
IEC 61373
| Basic Technical Parameters | ||
|---|---|---|
| Sr.No. | Parameters | |
| Electrical Requirement | ||
| 1 | Power Supply | 3 Phase, 415 V ±5%, 50 Hz ±3% |
| 2 | Power Consumption | 3.3 kW |
| Capacity | ||
| 1 | Cooling Capacity | 7 kW/2 Tr |
| 2 | Heating Capacity | 2.0 kW |
| Constructional Requirement | ||
| 1 | Design to Ambient (Cooling) | 50°C / 35°C |
| 2 | Max Operating Temperature | 60°C |
| 3 | Dimension (LxWxH) | 1308 x 1061 x 291 mm |
| 4 | Material for Housing | SS 304 grade S2 Confirming to IS:6911 |
| 5 | Noise Level(Inside the Coach) | 65 dB |
| 6 | Controller | Microprocessor Controller as per RDSO Spec. No.: RDSO/PE/SPEC/AC/0020-(latest) |
| 7 | Refrigrant | R-407C |
| 8 | Weight | 145 kg Approx. |
| Service condition | ||
| 1 | Ambient | -4 to 50°C |
| 2 | Max. Roof Temp. | 70°C |
| 3 | Train Speed | 160 Km/h |
| 4 | Relative Humidity | Up to 100% during rainy season |
| 5 | Atmosphere | Very dusty atmosphere with dust of composite brake block shoe. |
| 6 | Shock & Vibration Standard | IEC 61373 |